FULTON BOILER WORKS MODEL FBS
Design: 3 pass Wet Back Horizontal Firetube with corrugated furnace
Sizes: 30-400 Horsepower, steam or hot water, up to 300 psig
Features: Heavy Duty Construction, high efficiencies, standard gas & oil burners with low NOx options.
Request Information Back to top
|
|
|
|
|
FULTON BOILER WORKS MODEL RB
Design: 3 pass Wet Back Horizontal Firetube
Sizes: 30-400 Horsepower, steam or hot water, up to 300 PSIG
Features: Heavy Duty Construction, small foot print, high efficiencies, standard gas & oil burners with low NOx options.
Request Information Back to top
|
|
|
|

|
VERTICAL BOILERS
Designs: 15 - 300 PSIG Steam and Hot Water
Sizes:
- Tubeless Design 5 - 60 HP
- Multi-Pass Design 40 - 150 HP
Features: Skid mounted Boiler systems prepiped and wired, Low NOx burners
Request Information Back to top
|
 |
|
|
ELECTRIC BOILERS
Designs: 15 - 300 psig Steam and Hot Water
Sizes: 12 to 3375 KW (42 lbs/hr to 10,080 lbs/hr steam)
Custom design electrode boilers
Features: Multi-stage; SCR control option; Stainless steel elements
Request Information Back to top
|
|
|
|
|
PULSE COMBUSTION FIRETUBE BOILERS
Designs: 15 -150 psig Steam
Sizes: 500,000 - 750,000 BTU/Hr (13 - 17 HP)
Features: Sealed Combustion, Small diameter venting, Side Wall Venting, High Efficiency, Low NoX
Request Information Back to top
|
|
|
|
|
DEAERATOR MODEL FD-H
DESIGN: Tray type
SIZES: Horizontal design from 80 to 2500 horsepower, Vertical design from 4 to 160 horsepower
FEATURES: Heavy Duty fabrication of tank, stand and skid. Continuous re-circulation through tray section.
Request Information Back to top
|
|
|
 |
BOILER FEED & RETURN SYSTEMS
SIZES: 1 thru 500 HP
FEATURES: Fulton condensate return systems provide safe, trouble-free condensate return for boilers. Return systems are completely assembled with tank, stand, high pressure pump, motor strainer, float valve, shut-off valve, gauge glass assembly with overflow and drain openings.
Request Information Back to top
|
 |
  |
BLOWDOWN SEPARATOR
Purpose: Provide safe and effective means to collect and cool boiler blowdown to required temperature for drain. Flash steam is vented to atmosphere and cooled water goes to drain.
Features: ASME code Flash Tanks; Manual or automatic aftercooler options
Request Information Back to top
|
|
|
|
|
UNFIRED CLEAN STEAM GENERATOR
DESIGN: Horizontal or Vertical tanks with heating coils that utilize steam or high temp oil
SIZES: up to 6,000 lbs/hr of clean steam
FEATURES: Stainless steel construction for very high quality steam
Request Information Back to top
|
|
|
|
|
STEAM ACCUMULATORS
DESIGN: Wet or Dry type per your specifications
Request Information Back to top
|
|
|
|
|
STEAM SUPER HEATER
DESIGN: To your specification
Request Information Back to top
|
|
|
|

|
CHEMICAL FEED SYSTEMS
Purpose: provides means of injecting necessary chemicals into the feedwater tank and/or boiler to control corrosive gases and prevent scale formation in the boiler.
Request Information Back to top
|
|
|
|
|
FLASH TANK HEAT RECOVERY
Purpose: Similar to the Blowdown Heat Recovery system except for the addition of a ASME code flash tank to provide the added benefit of utilizing the flash steam from blowdown. Flash steam is piped to the deaerator or low pressure steam header.
Request Information Back to top
|
 |
 |
WATER SOFTENER
Purpose: Soften boiler feed water by exchanging hardness minerals (calcium and magnesium ions) with sodium ions forming a soluble non-scaling mineral that will not build up on hot surfaces. Softener systems include single or multiple resin tanks, brine system, salt storage, and automatic regeneration controls. Options include ASME tanks, special lining, skid mounting, and special controls.
Request Information Back to top
|
|
|
|
|
VICTORY ENERGY MODEL FRONTIER
DESIGNS: 3 or 4 pass Wet Back Firetube
SIZES: 200 to 2,500 Horsepower
FEATURES: Pressures up to 600 PSIG! Low NOx burners
Request Information Back to top
|
|
|
|
|
VICTORY ENERGY MODEL DISCOVERY WATERTUBE BOILER
DESIGNS: “D” type
SIZES: 30,000 TO 300,000 pounds per hour steam
Up to 1,050 degrees F super Heat
FEATURES: Burners from leading manufacturers
Request Information Back to top
|
|
|
|
|
VICTORY ENERGY MODEL VOYAGER WATERTUBE BOILER
DESIGNS: “O” type
SIZES: 25,000 TO 300,000 pounds per hour steam
Up to 1,050 degrees F super Heat
FEATURES: Burners from leading manufacturers.
Field erected models are available.
Request Information Back to top
|
|
|

Click on thumbnail to view larger
|
VICTORY ENERGY MODEL HORIZON HEAT RECOVERY STEAM GENERATOR
DESIGNS:
- 5,000 TO 300,000 pounds per hour of steam
- 100 to 1,500 PSIG
- Up to 1,500 degrees F. steam temperatures
FEATURES: Custom designs including:
- Gas/Oil supplementary firing
- Super Heaters
- Ductwork including expansion joints, support steel
- Integral feedwater economizers
- Free standing stacks with monitoring ports
- Integral Deaerator
- SCR system
- CO catalyst
Request Information Back to top
|
|
|
|
|
L.E.S. BOILER COMPANY
Design: 3 pass Scotch Box Firetube
Sizes: 480-4000 MBH, low pressure steam or hot water
Features: NARROW WIDTHS making this the ideal low pressure boiler replacement product that is factory assembled and test fired!
Request Information Back to top
|
|
|
|

|
INCLINED WATERTUBE BOILERS
Designs: 15 -150 PSIG Steam and Hot Water
Sizes: 15 - 21,000 MBH (3.7 - 514 HP)
Features: Straight Tube design; atmospheric or forced draft burners; Low NOx burners; highly resistant to thermal shock
Request Information Back to top
|
|
|
|

|
POTABLE WATER HEATERS
Purpose: Provide potable hot water on demand with or without storage tank utilizing an existing steam source. Provides temperature control of +-4 degrees F. from setpoint with steam condensate cooled to 200 degrees or less.
- Semi-instantaneous sizes to 300 gpm, single or double wall coil, vertical or horizontal configurations, packaged with valves and controls.
- Packaged storage water heaters with tanks to 5000 gallons
- Unfired clean steam generators, copper, cupro-nickle, or 316L coils
Request Information Back to top
|
 |
|
|
FLASH TANK HEAT RECOVERY
Purpose: Similar to the Blowdown Heat Recovery system except for the addition of a ASME code flash tank to provide the added benefit of utilizing the flash steam from blowdown. Flash steam is piped to the deaerator or low pressure steam header.
Request Information Back to top
|
|
|
|

|
DEAERATORS
Purpose: Remove corrosive gases from boiler feed water to protect against boiler and steam line corrosion; substantially reduce chemical usage and boiler blowdown requirements. Typical DA packages operate at 5-15 psi and include ASME storage tank, boiler feed pump(s), suction piping, control package, electrical panel and structural steel stand.
Applications: Fresh water makeup exceeds 25%; boiler operating pressure above15 psi; production depends on continuous operation.
Designs: Spray Head, Packed Column and Tray Type
Sizes: 3,500 - 280,000 lbs/hr. (Larger custom design sizes available)
Request Information Back to top
|
|
|
|
|
FEEDWATER SYSTEMS & CONDENSATE RECEIVERS
Purpose: Receive and store condensate return; provide fresh water makeup as required; Typical feedwater systems are vented to atmosphere and include non-ASME storage tank, boiler feed pump(s), suction piping, control package, electrical panel and stand. Steam injection preheat systems are often included to maintain minimum boiler water temperature.
Features: Vertical or horizontal tank configuration; lined, galvanized or stainless steel tanks
Request Information Back to top
|
|
|
|
|
SURGE TANKS
Purpose: Supplement DA storage capacity; collect low-pressure condensate returns. Provide continuous makeup to deaerator reducing DA tank size; Typical surge tank systems are vented to atmosphere and include storage tank, transfer pump(s), suction piping, control package, electrical panel and stand.
Sizes: 300 - 3000 gallon storage tanks
Request Information Back to top
|
|
|
|

|
BLOWDOWN VALVES
ASME Blowdown valves, quick and slow opening
Request Information Back to top
|
 |
|

|
BLOWOFF HEAT RECOVERY
Purpose: Recover waste heat from continuous boiler surface blowdown by preheating boiler feed water before it enters feedwater tank or DA. Units automatically control blowdown rate to maintain desired level of dissolved solids in boiler water and recover up to 90% of available heat normally lost to drain.
Request Information Back to top
|